In integrated mode the PACS’s launch action supplies the command line (in Merge RPACS that’s a macro); in standalone mode a desktop shortcut does. DSFX Send needs a source archive to run — set it with DSFXSource in the INI or -DSFXSource on the command line (see below).

Any setting can be a switch. Every configuration setting has a matching -DSFXName switch — the full list, with defaults and precedence, is on the Settings page. This page focuses on the launch-time switches (the exam and the operator) that the PACS supplies when it opens DSFX Send, plus worked examples.

The source archive

SwitchMeaning
-DSFXSource=AE@host:portRequired unless set in the INI. The PACS archive to search and pull from — an AE@host:port, or the name of a [DICOM] entry in DocScan.ini. Legacy spelling: -archive.

Launch-time switches (the exam and the operator)

These describe the exam being opened and who is opening it. They are per-launch, so they live only on the command line — the PACS supplies them when it opens DSFX Send for a study.

SwitchMeaning
-SIUID … -Accession … -MRN …Open a specific exam or patient (integrated mode). Supplied by the PACS when it launches DSFX Send (in Merge, a macro).
-IPID … -Name … -DOB …Additional patient details from the PACS launch (shown in the header and used for related-exam matching).
-DSFXUsername "name"Record this operator name in the log and audit events instead of the Windows login — useful on shared workstations. Integrated mode only; ignored in standalone mode. Does not change file paths. Legacy spelling: -username.
-DSFXSelectedDestination "name"In integrated mode with a single exam, send that whole study at once (no clicks), opening in the send monitor (see Send). As an INI setting it only pre-selects the destination; the one-click auto-send is triggered by this command-line form. Legacy spelling: -SelectedDestination.

For destinations, AE title, history, audits, certificates, updates and advanced search, use the matching -DSFX… switch or the INI line — see Settings.

Examples

Standalone, reading destinations from a server:

DSFX-Send.exe -DSFXSource=ARCHIVE_AE@10.1.2.3:104
              -DSFXDestinations=https://pacsserver/

Integrated, as the PACS launches it for one exam:

DSFX-Send.exe -DSFXSource=ARCHIVE_AE@10.1.2.3:104
              -DSFXDestinations=https://pacsserver1/
              -DSFXDestinations2=https://pacsserver2/
              -DSFXLocalAe=RADWS07
              -SIUID 1.2.840.113...

Integrated, sending one study straight to a destination (no clicks), with the operator recorded:

DSFX-Send.exe -DSFXSource=ARCHIVE_AE@10.1.2.3:104
              -DSFXDestinations=https://pacsserver1/
              -DSFXLocalAe=RADWS07
              -SIUID 1.2.840.113...
              -DSFXSelectedDestination "Main Reading PACS"
              -DSFXUsername "{$userNoDomain}"
That {$userNoDomain} is a PACS variable. In integrated mode you don’t type a name — you pass the PACS’s own “logged-in user” variable, and the PACS substitutes the real user when it launches DSFX Send. In Merge RPACS that variable is {$userNoDomain} (the user name without the domain). Other PACSs have their own equivalent. The same applies to -SIUID: a Merge macro passes {$0020,000d} there rather than a literal study UID.

Nothing on the command line at all — everything comes from DocScan.ini (see the Settings page for the matching [COMMON] block):

DSFX-Send.exe
Older switch names still work. Existing macros and shortcuts that use the earlier spellings (-archive, -destinations, -localae, and so on) keep working unchanged — the Settings page lists each one. Prefer the -DSFX… names for anything new.

← The applicationFiles & folders →